MITSUBISHI MELSEC PLC FX3G-24M FX3S-30M FX3S-10MR FX3S-14MR-ES Programmable Controller Mitsubishi Electric FX3G FX3U FX3G-1DA FX3G-1AD
Mitsubishi Electric MELSEC FX3G and FX3S compact PLCs are current-generation Japanese-OEM programmable controllers stocked by Flextech Industrial Supplies for Malaysian machine builders requiring 10-128 I/O compact PLC platforms with built-in USB programming, high-speed pulse output, and analog expansion capability – the FX3 generation successors to the widely-installed FX2N compact PLC in Malaysian manufacturing.
FX3G and FX3S are in current active production status from Mitsubishi Electric – unlike the legacy FX2N (mature/end-of-new-design), FX3G and FX3S carry full Mitsubishi Electric warranty, current firmware, and GX Works2 engineering tool support. Flextech quotes FX3G and FX3S models with same-day Klang Valley dispatch on standard configurations from Puchong, Selangor.
FX3G and FX3S Model Specifications
| Model | I/O Points | Output Type | HSP Output | Built-in USB | DIN Rail Width |
| FX3G-24MR | 14 in / 10 out relay | Relay | No (relay) | Yes | 130 mm |
| FX3G-24MT | 14 in / 10 out transistor | Transistor sink | 3-axis 100 kHz | Yes | 130 mm |
| FX3S-10MR | 6 in / 4 out relay | Relay | No | Yes | 60 mm |
| FX3S-14MR-ES | 8 in / 6 out relay, CE | Relay | No | Yes | 80 mm |
| FX3G-1DA | 1-ch analog out | 0-10V / 4-20mA | – | – | Right-side expansion |
| FX3G-1AD | 1-ch analog in | 0-10V / 4-20mA | – | – | Right-side expansion |
FX3G Compact PLC: 14-128 I/O Mid-Range
FX3G-24M (the “M” designates the main unit, suffix R = relay, T = transistor) provides 24 I/O in a compact DIN rail housing – the entry FX3G main unit for Malaysian machine automation requiring USB programming, RS-422 communication, and optional analog and Ethernet expansion.
High-speed pulse output on FX3G-24MT: The transistor output variant provides 3-axis simultaneous pulse output at 100 kHz – used for stepper motor driver and compatible servo drive step/direction positioning. A Malaysian packaging machine with 3 positioning axes (X, Y, and index table) can use a single FX3G-24MT as the motion controller, eliminating a dedicated motion module for applications where 100 kHz pulse rate is sufficient.
Ethernet option: FX3G-ENET-ADP adapter plugs into the FX3G left-side communication port, adding 10BASE-T/100BASE-TX Ethernet for SCADA Modbus TCP connectivity, GX Works2 remote programming, and MELSOFT Navigator HMI connection. This is the only way to add Ethernet to FX3G – the FX3S platform does not support Ethernet expansion.

FX3G Analog Expansion Modules
FX3G-1DA (1-channel analog output):
- Output range: 0-10 VDC or 4-20 mA (switch-selectable)
- Resolution: 12-bit (0-4,095 counts over the output range)
- Common use: inverter speed reference (4-20 mA → FREQROL analog input), proportional valve control (0-10 V → valve amplifier)
- Mounts directly on FX3G right-side port – no extension cable required
FX3G-1AD (1-channel analog input):
- Input range: 0-10 VDC or 4-20 mA (switch-selectable)
- Resolution: 12-bit (0-4,095 counts)
- Common use: pressure transmitter feedback (4-20 mA), thermocouple amplifier output (0-10 V), load cell signal conditioner
- FX3G PLC PID ladder instruction reads FX3G-1AD value → computes output → writes to FX3G-1DA → adjusts FREQROL speed → closed-loop process control
Malaysian machine builders use FX3G + FX3G-1AD + FX3G-1DA as a complete single-PLC closed-loop process controller for temperature, pressure, or flow control loops in packaging, food processing, and chemical applications.
FX3S Compact PLC: 10-30 I/O Entry Compact
FX3S-10MR – the smallest FX3 main unit: 10 I/O (6 inputs + 4 relay outputs) in a 60 mm DIN rail width. Suited for Malaysian simple machine safety logic, indicator sequencing, and 2-4 relay output control where FX3G’s 24 I/O minimum exceeds requirements.
FX3S-14MR-ES – 14 I/O (8 inputs + 6 relay outputs) with the -ES (European Safety) compliance documentation package: CE marking, EMC declaration of conformity (EN 61131-2), and RoHS documentation. -ES models are specified by Malaysian OEM machine builders supplying CE-required European or Australian markets where the complete CE compliance documentation set is required for machine technical file.
The FX3S does not support right-side analog expansion (FX3G-1DA/1AD are not compatible with FX3S). For FX3S analog requirements, use FX3S-CNV-ADP + external analog I/O unit on RS-485, or upgrade to FX3G platform.

Programming
FX3G and FX3S use GX Works2 – the current Mitsubishi IEC 61131-3 programming tool for FX-series (ladder, SFC, structured text). Built-in USB mini-B port on both FX3G and FX3S connects to laptop without dedicated RS-422 programming cable. GX Works2 provides simulation mode (offline program test without PLC hardware) – useful for Malaysian machine builders commissioning programs before machine delivery.
Indicative Pricing
| Model | Price Range (MYR) |
| FX3G-24MR (relay) | RM 2,200-3,500 |
| FX3G-24MT (transistor) | RM 2,400-3,800 |
| FX3S-10MR | RM 1,200-2,000 |
| FX3S-14MR-ES | RM 1,400-2,200 |
| FX3G-1DA | RM 600-1,000 |
| FX3G-1AD | RM 600-1,000 |
Contact Flextech for current pricing and stock confirmation.
How to Order
Flextech provides FX3G and FX3S quotations within 24-48 hours. Specify the full model number including output type suffix (R/T) and compliance variant (standard/-ES). Flextech confirms stock, pricing, and compatible expansion module availability.
For the full compact PLC product range including FX2N legacy, see [Mitsubishi FX2N FX3G FX3S PLC](/product/mitsubishi-fx2n-fx3g-fx3s-plc-malaysia/). For the programmable controller category, see [programmable controllers Malaysia](/product-category/plc/).
Mitsubishi FX3G FX3S FAQ
What is the I/O count and output type of the FX3G-24M?
24 total I/O: 14 inputs + 10 outputs. FX3G-24MR = relay outputs. FX3G-24MT = transistor sink, enables 3-axis 100 kHz pulse output for stepper/servo positioning.
What is the maximum I/O for FX3G?
128 total I/O with expansion units. Main unit available in 14-80 I/O configurations.
Does FX3S-14MR-ES support Modbus TCP?
No Ethernet on FX3S. Supports RS-485 Modbus RTU via FX3S-CNV-ADP + adapter. For Ethernet, upgrade to FX3G + FX3G-ENET-ADP.
What does -ES suffix mean on FX3S-14MR-ES?
European Safety compliance package – CE marking, EMC declaration (EN 61131-2), RoHS documentation. Required for Malaysian OEM machines supplied to European or CE-required markets.
What analog expansion is available for FX3G?
FX3G-1DA (1-ch analog output, 0-10V/4-20mA), FX3G-1AD (1-ch analog input, 0-10V/4-20mA). Both mount directly on FX3G right-side expansion port. Not compatible with FX3S.
MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.

Reviews
There are no reviews yet.